PDT3100 Scanners Setup
Load Scanner PDT 3100 Documentation
Machine used:
OS: Microsoft Windows 98-Second Edition 4.10.2222 A
Intel Celeron Processor- 128.0 MB RAM
File System: FAT 32
Virtual Memory: MS-DOS compatibility mode
Use “Null Modem” cable to connect to PC.
Software Loaded: VHTP3140.HEX
(Verify that hex file to be loaded is date 11/17/1999 716Kb)
Procedure:
Load program onto handheld.
Press <Pwr> to turn off the handheld
Press and hold the <F><I>keys and then press and release the <Pwr> button while holding the other keys. Then release the <F><I> keys.
This will put the handheld into the “COMMAND MODE” screen.
Select the “Program Loader”(Use the down arrow t display the option on the screen and then press <Enter> to select it.)
When the screen says “Program Loader”, make sure the handheld is in the cradle.
At the “warning: EFPROM will be erased, continue?” prompt, press <Enter> to erase the EFPROM. This will take a minute or so to erase. (If the software was previously wiped out then this message will not appear.)
At the “Comm Parameters Baud” prompt, set the baud rate to 19,200(Or whatever the rate is on Dos screen on PC). (press the up arrow to do so).
Set the "Databits=7", "Parity=odd" and "Flow Control=Xon/Xoff" prompts until it displays “Receive:" on the receiving screen.
Note: if the screen shows "Awaiting DSR" then the handheld does not have a good connection to the PC, check all connections and make sure cables are secure and null modem is in place.
Get the PC (Windows 98-Second Edition) ready to transfer the information: this must be done in a certain time frame or the scanners will time out. Sometimes it’s best to have this part ready to hit enter to begin the transfer.
Open a dos window (Start-run-type 'command') and go to the symbol directory containing the sendhex.exe and send.bat files. (At the prompt type 'cd 3140') .
At the prompt, type "send" and hit <enter>. This will start the PC portion of the transfer program.
On the PC, hit enter and the program should begin to upload and show percentage of completion.
On completion of a good transfer, handheld will display a status of "0000".
Set up for handheld operation:
After the program has been uploaded to the handheld, a warm boot will be needed.
Press <Pwr> to turn off the handheld
Press and hold the <4><5> keys and then press and release the <Pwr> button while holding the other keys. Then release the <4><5> keys.
Several things will begin to scroll across the scanner screen. It will finally bring up the CONFIG MENU
Select the "Local IP Address" option from the "Config Menu".
Enter the appropriate settings for the following:
IP Address: 999.999.999.999( Address for handheld)
IP Router: 999.999.999.999( Address of the router/gateway for the network)
IP Netmask: 255.255.255.0 (Subnet mask)
Press <CTL>then <S> to save the changes.
(IPs for Lockbourne the setup would be like the following
192.168.1.185
192.168.1.200
255.255.255.0
)
Select the "Domain" option from the "Config Menu" and enter the IP Address for DNS servers (192.168.0.254 ; 192.168.0.224).
Select the "Remote IP Address" option from the "Config Menu".
There need to be 2 options set up. “RBeacon” and “Accellos”
Enter "RBeacon" as the "Config Host".
Enter the appropriate settings for the following:
Remote IP Address: 192.168.0.253 (Address of the PC that runs the telnet server / RFBase)
Server Alias Name: RBeacon
Port# 23
Terminal type: VT220 (press <CTL> then< N> to select) (press <CTL> then< N> again to select next option)
Move down to next blank position on screen and press Enter
Enter "Accellos" as the "Config Host".
Enter the appropriate settings for the following:
Remote IP Address: 192.168.0.20 (Address of the PC that runs the telnet server / RFBase)
Server Alias Name: Accellos
Port# 23
Terminal type: VT220 (press <CTL> then< N> to select) (press <CTL> then< N> again to select next option)
Press <CTL>then <S> to save the changes and return to the "Config Menu" screen.
Select the "Network ID" hex code. It should be the same as in the Access Point Configuration ( default 101).
Press <CTL> then <S> to save the changes and return to the "Config Menu” screen.
3. Move down to next blank position on screen and press Enter
Enter "RF Host" as the "Config Host".
Enter the appropriate settings for the following:
Remote IP Address: 192.168.0.101 (Address of the PC that runs the telnet server / RFBase)
Server Alias Name: RF Host
Port# 23
Terminal type: VT220 (press <CTL> then< N> to select) (press <CTL> then< N> again to select next option)
Press <CTL>then <S> to save the changes and return to the "Config Menu" screen.
Select "Exit" option from the "Config Menu".
Scanner should then ask for a reboot. Press <Y> to reboot.
Scanner should be ready for operation
To set IP address to a handheld already loaded:
FUN-- CTL--- R one of the time
Pssword: system
Main Menu --Config Menu --- Local IP Address
Set new configuration, then
CTL—S to Save
Reboot ? -- Y